HONcode

This website is certified by Health On the Net Foundation. Click to verify. This site complies with the HONcode standard for trust worthy health information:
verify here.


Search only trustworthy HONcode health websites:

Affiliations

REACTION is affilliated with these programs and organisations:

REACTION is delivering better and more efficient healthcare services in Europe, thus supporting the Commissions activities in ICT for Health: eHealth.



The REACTION platform allows for the creation of inclusive applications with accessibility for all. The project supports the Commissions campaign: eInclusion - be part of it!



Sign In

Enter Username

Password



Forgotten your password?
Request a new one here.

Facts



The REACTION project is a 4-year project started in 2010. It is partly funded by the European Commission under the 7th Framework Programme in the area of Personal Health Systems under Grant Agreement no. 248590

 Impressum   Privacy

Previous Newsletters


Read previous issues of our newsletter here:

April 2014
August 2013
June 2012
August 2011
April 2011
November 2010

Share this

Bookmark and Share

eHealth at Facebook

Join the discussion on EC eHealth at Facebook!

Downloads: A minimally invasive chip based near infrared sensor for continuous glucose monitoring

Downloads Home > Scientific conference papers > A minimally invasive chip based near infrared sensor for continuous glucose monitoring

A minimally invasive chip based near infrared sensor for continuous glucose monitoring


Abstract: Assessment of glycaemia in diabetes is crucially important for prevention of both, acute and long term complications. Continuous glucose monitoring (CGM) is certainly the most appropriate way for optimizing the glycaemic control, since it prevents or delays the progression of complications associated with hypo- or hyperglycaemic events, reducing morbidity, mortality, and overall costs in health care systems. In this paper we describe the concept and first in vitro results of a minimally invasive, chip-based NIR-Sensor for continuous glucose monitoring. The sensor concept is based on difference infrared absorption spectroscopy, which was evaluated within laboratory measurements of D+-Glucose dissolved in water. The laboratory measurements revealed a linear relationship between glucose concentration and the integrated difference spectroscopy signal with a coefficient of determination of 99.6% in the concentration range of 0- 500 mg/dL. Suitable wavelength bands were identified in which the correlation is preserved and commercial light sources are available for realisation of a spectrometer-less, integrated NIR-sensor. In the designed sensor the component area (non-disposable) is separated from the detection area (disposable, low-cost). The disposable part of the sensor is fluidically connected to a micro-dialyses needle, accessing glucose subcutaneously via the ISF (interstitial fluid) or intravascularly. The non-disposable part contains all the optical elements, like LED´s and photo-detectors. The in- and out-coupling of the optical signal is achieved across the plane of the chip by using total internal reflection on mirrors integrated into the fluidic chip. The glucose is continuously measured by considering the difference signals of light at the corresponding wavelengths, as a function of time or in defined intervals if the light sources are modulated. The in-vitro measurements show an absolute error of about 5 mg/dL with a relative error of 5% for glucose concentrations larger than 50 mg/dL and about 12 % in the hypoglycemic range (<50 mg /dL).
Created:

09. August 2013 11:10
Downloads
Download 2344
Info
License: Spie subscriber
O/S: pdf

Download:
Download
Download Stats Downloads: 113
Downloaded: 383744
Most Downloaded: REACTION brochure [ 30121 ]
Most Recent: REACTION brochure [ 30121 ]